Australia, New Zealand, United States, United Arab Emirates, Saudi Arabia, India, Malaysia

 

Home | The System  I Products | Services | Customers | Support | About Us | Contact Us




 
 
 
   
   
   
   
 

 Industrial

 

Temperature measurement and monitoring is an integral part of Industrial processes to ensure conformance to product quality standards.

The TEMPoTrack® Industrial Temperature Monitoring System fully automates temperature monitoring and recording. The system provides auditable records for effective temperature management. The unique alarm handling system provides the alarm duration, min/max temperatures and temperature profile in the event of an alarm. If an alarm is raised when the business is unattended, the optional alerting function can call a series of pre-programmed phone numbers.

The System can support different types of temperature sensors eg. RTD, thermocouple.

  • Laboratories
  • Wineries
  • Food Processing Plants
  • Meat Processing
  • Museums
  • Greenhouses
  • Equipment Rooms
  • Warehouses
  • Chemical Process Monitoring
  • Server Rooms

BENEFITS

  • fully automate temperature monitoring and recording 24/7 or according to a user defined duration.
  • provide auditable records for effective temperature management.
  • prevent the potential loss of costly temperature sensitive items.
  • monitor and record the temperature profile during a process.
  • high precision temperature monitoring (down to +/- 0.1oC accuracy).

HOW IT WORKS

  • It logs the temperature readings together with the time stamps according to the Logging Interval specified by the user.
  • It continuously monitors the temperature for Out Of Range (OOR) conditions. OOR conditions occur when the temperature exceeds the user specified upper or lower alarm limits.
  • When OOR conditions are detected, logging will occur according to the Out Of Range Logging Interval. This unique feature enables the TEMPoTrack® to capture the temperature profile of OOR conditions. The duration of the OOR condition and the minimum or maximum temperature (lower or upper alarm limit exceeded) are also stored.
  • An alarm is raised only if the duration of the OOR condition exceeds the Alarm Delay duration. This allows the user to filter temporary fluctuations in temperature above the alarm limits (eg. defrost cycle in a refrigerator) as “uneventful alarms”.
  • When temperatures fall back within the upper and lower alarm limits, logging reverts back to the normal Logging Interval.
  • Logged data can be viewed on the logger and on the computer where connected.

For a software demonstration click here.

 

 

 

PRODUCT RANGE

 

Product Description Examples of Applications
Button Logger

(More product details)

Button sized temperature loggers comes in a durable stainless steel package and is highly resistant to environmental hazards such as dirt, moisture and shock. It is easily attached to perishable goods or temperature sensitive products and is ideal for monitoring temperature during transportation. Data is transferred between the button logger and a computer with a momentary contact to a probe connected to the computer. Suitable for small, medium and large businesses transporting products (data needs to be manually downloaded though)
Standalone System

(More product details)

The standalone TEMPoTrack® Temperature Logger is suitable for businesses that do not have a PC. The logger is equipped with a user friendly menu system for configuration set-up. Logged temperature data and alarms can be viewed on the LCD display of the logger. The extensive alarm handling capabilities include a visible alarm indicator. A flashing alarm indicates that an alarm condition has occurred. The alarm details including the time stamp, duration, temperature profile and min/max temperature can be viewed on the alarm log. Suitable for laboratories, chemical plants, wineries, and meat processing  premises that do not have a computer (data needs to be manually downloaded though)
Point to Point System

(More product details)

In a Point-to-Point TEMP°Track® Monitoring System, temperature readings are transmitted and displayed on a PC or a touchscreen display unit continuously, enabling remote monitoring of the temperature levels and alarm conditions from the PC. The ability to visualise temperature profile and alarm information enables quick interpretation of data to determine product quality and integrity.

This system is highly recommended for applications requiring auditable records as it fully automates data collection and processing. Graphical data and statistics provided can also be used to monitor potential equipment failure allowing for pre-emptive maintenance to be scheduled to prevent costly breakdown of machinery and consequent loss of products.

 

Suitable for ie.  laboratories, chemical plants, wineries, and meat processing  premises that require monitoring of one refrigerator and would like to view live and historical temperature data in graphical/report form on a computer
Point to Multi Point System

(More product details)

As the number of monitoring points increases, the Point-to-Point system can be expanded to a Point-to-Multi Point Monitoring System by introducing additional logger units. The point to point system is the base system as described above. Suitable for ie.  laboratories, chemical plants, wineries, and meat processing  premises that require monitoring of more than one refrigerator within the same location, and would like to view live and historical temperature data in graphical/report form on a computer
Network System

(More product details)

Our TEMP°Track® Network systems enable central administration of a cold chain management process that spans multiple locations.

The Point-to-Point /Multi Point systems at each site are connected via the Internet, a Local Area Network (LAN) or a Wide Area Network (WAN) to an administration centre.

Temperature measurements are automatically collected per site and archived to the administration centre periodically.

 

Suitable for groups of premises in different locations where local and central viewing and/or management of temperature data is necessary

Note: For Point-to-Point, Point-to-Multi Point and Network Systems, TEMP°Track® systems can be connected to a computer through any of the following interfaces:

  • Wired access – Serial port access to the Logger via a serial cable. Maximum distance between logger and PC is up to 10m only.
  • Wireless access – Communication between logger and PC up to 100m line of sight, longer distances up to 5km possible with high gain wireless modules with external antenna.
  • GPRS access – Communication between logger and PC can be established anywhere within coverage of the public mobile network.
  • Ethernet access – Communication between logger and PC can be established by connecting the logger directly to any ethernet port on a computer network.
 

                                                       © 2003-2008. All Rights Reserved. E2E IT Solutions Pty Ltd  ABN 13 103 708 541      Contact  I  Legal  I  Sitemap  I  Help  I  Top